site stats

Cisco grounding requirements

WebNov 1, 2024 · 17.60 inches (44.70 cm) for the Cisco ASR 9910 Router. To mount the router in a 4-post rack, the usable aperture (the width between the inner edges of the two mounting flanges) must be at least 17.75 inches (45.09 cm) for the Cisco ASR 9922 Router or Cisco ASR 9912 Router. WebMar 17, 2024 · Cisco Catalyst 9500 Series High Performance switch with optional network module 1 (power supply and fan modules not shown) 8. Two M4.0 x 20mm Phillips pan-head screws (Black color) 2 . Product documentation and compliance document. 9 . Ground lug and two M4.0 x 8mm Phillips pan-head screws. 3 . Two 19-inch mounting brackets

Power and Cooling Requirements - Cisco

WebMar 2, 2024 · Ground lug and screws (provided with the access point) Yes. Wall Mount Bracket. Yes. Four M6 x 12–mm Hex-head Bolts. Yes. Crimping tool for ground lug, Panduit CT-720 with CD-720-1 die No. Four wall mounting screws. No. Four wall anchors (specified for all material) No WebFeb 15, 2024 · Make sure to follow any grounding requirements at your site. Step 1 Use the ground lug screw and the lug ring for a single-ground connection. Use the dual-ground adaptor and dual-hole lug for a dual … how long after bed bug bite does it itch https://americanffc.org

Catalyst 3750-X and 3560-X Hardware Installation …

WebSep 14, 2024 · Cisco ASA 5512-X, ASA 5515-X, ASA 5525-X, ASA 5545-X, and ASA 5555-X Hardware Installation Guide ... The ASA 5500-X models equipped with AC-input power supplies are shipped with a 3-wire electrical cord with a grounding-type plug that fits into a grounding-type power outlet only. ... The topics in this section describe the … WebGuidelines and Best Practices for the Installation and ... - Cisco WebMay 22, 2013 · 05-22-2013 06:49 PM. No... grounding is only required on outdoor equipment, access points and or antennas. 05-23-2013 04:46 PM. No the grounding is … how long after beer breastfeed

Catalyst 3650 Switch Hardware Installation Guide

Category:Hardware Installation Guide for Cisco 8200 Series …

Tags:Cisco grounding requirements

Cisco grounding requirements

Cisco Nexus 5000 Series Hardware Installation Guide

WebApr 4, 2024 · Alternatively, you can ground the chassis by using a customer-supplied grounding cable that meets your local and national installation requirements. For U.S. installations, we recommend 6-AWG wire. Connect your grounding cable to the chassis with a grounding lug (provided in the switch accessory kit) and to the facility ground. Note WebDec 2, 2003 · Cisco recommends to use the grounding holes on their equipment to connect a grounding lug. The nice thing is that these lugs are never in the box, …

Cisco grounding requirements

Did you know?

WebMar 17, 2024 · When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046 Warning To reduce risk of electric shock or fire, installation of the equipment must comply with local and national electrical codes. Statement 1074 Warning WebFeb 11, 2024 · – AWG 18 (1 mm ) or larger wire for EN/IEC 60950-compliant chassis grounding For NEC-compliant grounding, an appropriate user-supplied ring terminal, with an inner diameter of 1/4 in. (5 to 7 mm) In addition, depending on the type of modules you plan to use, you might need the following equipment to connect a port to an external …

WebNov 17, 2024 · Grounding is not always required for indoor installations because access points are classified as low-voltage devices and do not contain internal power supplies. However, electrical grounding is always recommended for outdoor access points. It is always best to check with local electrical standards to determine if grounding is necessary. WebGeneral power and grounding requirements are: Installation of the routing system must follow national and local electrical codes: In the United States: United States …

WebMar 13, 2024 · 1. Throughput measured with 1500B User Datagram Protocol (UDP) traffic measured under ideal test conditions. 2. “Multiprotocol” refers to a traffic profile consisting primarily of TCP-based … WebNov 2, 2007 · To attach the grounding wire to the grounding receptacle on the Cisco 10005 DC PEM, perform these steps: Step 1 Set the DC PEM power switch (or switches) to the Off position. Step 2 Turn all three …

WebJan 26, 2024 · The switch meets the voltage dips and interruptions requirements of IEC 61850-3 only when powered by a redundant power supply configuration. If you are responsible for the application of safety-related programmable electronic systems (PES), you need to be aware of the safety requirements in the application of the system and be …

how long after baby drops is birthWebFeb 24, 2024 · Insert the stripped end of the grounding cable into the open end of the grounding lug. Step 3: Use the crimping tool to secure the grounding cable in the grounding lug. Step 4: Attach the ground … how long after bbl can u sitWebDec 2, 2003 · Cisco recommends to use the grounding holes on their equipment to connect a grounding lug. The nice thing is that these lugs are never in the box, according to Cisco 'the grounding lugs are not available from Cisco Systems; any electrical-connector vendor can provide this lug'. how long after bankruptcy are you dischargedWebFeb 27, 2024 · Make sure that you follow grounding requirements, if any, at your site. Step 1 Use the ground lug screw and the lug ring for a single-hole ground connection. Use the dual-hole lug for a ground connection … how long after being charged until court dateWebJan 26, 2024 · 2 Use a screwdriver to remove the port cover and access the port. 3 Use a screwdriver to remove the port cover and access the port. Ports. Note: Different configurations are available. Not all ports or slots are present in all configurations. 1G SFP/ 10G SFP+ Ports (Uplinks) how long after bankruptcy can i buy a new carWebFeb 11, 2024 · General power and grounding requirements are: Installation of the Cisco CRS 16-Slot Line Card Chassis Enhanced router must follow national and local electrical codes: In the United States—United States National Fire Protection Association (NFPA) 70 and United States National Electrical Code (NEC) how long after biometricsWebSwipe Call, Inc. DBA nthere. Jul 2008 - Present14 years 4 months. Los Angeles, California, United States. We are hand picked, talented IT/Network, and telecommunications consulting engineers. We ... how long after bankruptcy